001079.03

John Deere 001079.03 – ATC: ATC Sensor Supply Voltage High

Issue description

The Automatic Temperature Control (ATC) or ClimaTrak™ control module has detected that the supply voltage to one of its sensors is above the expected range. This 'Sensor Supply Voltage High' condition typically indicates an open circuit, a faulty connection, or a failed sensor within the heating and air conditioning system.

Applies to these machines

  • 7715
  • 7815
  • 7720
  • 7820
  • 7920
  • 9430
  • 9530
  • 9630
  • 9320T
  • 9420T
  • 9520T
  • 9620T
  • 5225
  • 5325
  • 5425
  • 5525
  • 5603
  • 5625

Check the cause

  1. Restart the tractor to see if resetting the system's communication messages clears the code

  2. Visually inspect the wiring harnesses and connectors associated with the ClimaTrak™ system sensors for signs of damage, corrosion, or debris

  3. Check for open circuits or faulty connections in the sensor supply circuit

  4. Measure individual sensor output voltages to determine if a reading is fixed at a high voltage regardless of changing conditions

Repair steps

  1. Restart system

    Restart the tractor to reset communication messages and verify if the fault code is active or stored.

  2. Inspect wiring and connectors

    Visually inspect the ClimaTrak™ sensor wiring harnesses and connectors. Repair any damaged wires, clean corrosion, and remove debris to ensure solid connections.

  3. Test sensor voltage

    Measure the output voltage of the ATC sensors. A persistently high reading that does not change with environmental conditions (e.g., a temperature sensor stuck at 4.5V when hot) indicates a failed sensor or open circuit.

  4. Seek professional diagnosis

    If basic wiring checks do not resolve the issue, contact a John Deere dealer. Specialized diagnostic tools are required to pinpoint the exact malfunctioning sensor or circuit for replacement.

Parts you might need

(2)

Get help to fix this fault by requesting a quote