1079

John Deere 1079: Height Sensor Power Voltage Too High

Issue description

The voltage supplied to the Height Sensor Power circuit is greater than 5.25VDC, which is above the acceptable range. This may be caused by a faulty voltage regulator in the Header Control Unit or a short in the wiring of the circuit.

Check the cause

  1. The voltage regulator of the Header Control Unit

  2. The wiring associated with the Height Sensor Power circuit

Repair steps

  1. Inspect

    Inspect the voltage regulator of the Header Control Unit for signs of damage or failure.

  2. Test

    Test the wiring of the Height Sensor Power circuit for shorts or other electrical faults.

  3. Replace

    If the voltage regulator is faulty, replace it with a compatible replacement.

  4. Repair

    If a short is found in the wiring, repair or replace the affected wiring.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other John Deere codes