ACU001080.03

John Deere ACU001080.03 – ACU: ACU Sensor Supply 2 Voltage High

Issue description

The Armrest Control Unit (ACU) has detected that the voltage on the 'Sensor Supply 2' circuit is above the expected range (Voltage High). This circuit provides regulated power to a specific group of sensors. The issue could stem from a short to a higher voltage source, a faulty sensor on the circuit, or an internal fault within the ACU itself.

Applies to these machines

  • 7630
  • 7730
  • 7830
  • 7930
  • 8130
  • 8230
  • 8330
  • 8430
  • 8530
  • 8235R
  • 8260R
  • 8285R
  • 8310R
  • 8335R
  • 8360R
  • 9230
  • 9330
  • 9430
  • 9530
  • 9630
  • 7810

Check the cause

  1. Restart the tractor to cycle power and see if the intermittent error clears

  2. Perform a visual inspection of the batteries and alternator for loose connections, corrosion, damage, or accumulated debris

  3. Check fuses F22 and F24, which are often related to communication codes

Repair steps

  1. Identify sensors

    Consult the specific tractor's technical manual or wiring diagram to identify all sensors powered by the 'ACU Sensor Supply 2' circuit.

  2. Isolate faulty sensor

    Disconnect sensors on the Supply 2 circuit one by one to see if the fault code clears. If the code clears upon disconnecting a specific sensor, that sensor is likely faulty.

  3. Test wiring harness

    Test the wiring harness for shorts to power or ground between the ACU and the sensors.

  4. Replace ACU

    If the wiring and all sensors are confirmed to be good, the Armrest Control Unit (ACU) itself may be faulty and require replacement.

Parts you might need

(2)
  • Supersedes RE243770. Used for detecting the position of various controls on the armrest.

  • Crankcase Pressure Sensor

    Potential component on this circuit based on similar models; verify with specific machine wiring diagram.

Get help to fix this fault by requesting a quote