John Deere 1080 – Header Control Unit (E01): Height Sensor Power 2 Voltage Too Low
Issue description
The voltage for Height Sensor Power 2 has dropped below the acceptable threshold of 4.75VDC. This specific power circuit is responsible for supplying power to both the CONTOUR MASTER™ Angle Sensor and the Header Raise Pressure Sensor. The underlying cause is typically a short circuit to ground in the associated wiring or a faulty voltage regulator within the Header Control Unit.
Applies to these machines
4 machines- 9560 STS
- 9660 STS
- 9760 STS
- 9860 STS
Check the cause
Enter diagnostic mode on the combine's display to view the status of the Header Control Unit (E01) and check the real-time voltage of 'Height Sensor Power 2 (cc# 471)'. A normal reading should be between 4.8 and 5.2 VDC.
Inspect the wiring harness connected to the CONTOUR MASTER™ Angle Sensor and the Header Raise Pressure Sensor for any signs of damage, abrasion, or loose connections.
Test the wiring for a short circuit to ground, as this is a common cause for the voltage to drop.
Check for any other related fault codes on the display.
Check sensor calibration, as an improperly calibrated CONTOUR MASTER™ system can sometimes trigger related fault codes.
Repair steps
Disconnect power
For safety, disconnect the battery before beginning any electrical repairs.
Isolate the fault
Disconnect both the CONTOUR MASTER™ Angle Sensor and the Header Raise Pressure Sensor. Turn the machine's key to the 'RUN' position without starting the engine. Measure the voltage on the 'Height Sensor Power 2' circuit. If the voltage returns to the normal range (4.8-5.2 VDC), one of the disconnected sensors is likely faulty and causing the short. Reconnect them one at a time to identify which one causes the voltage to drop. If the voltage remains low with both sensors disconnected, the issue is likely in the wiring harness or the Header Control Unit itself.
Repair or replace wiring
If a short or damage is found in the wiring harness, repair the affected section or replace the harness if the damage is extensive.
Replace faulty sensor
If a specific sensor was identified as the cause of the fault during the isolation step, replace it with a new OEM part.
Address the Header Control Unit
If the wiring and sensors are determined to be in good condition, the fault likely lies with the voltage regulator within the Header Control Unit. Depending on the specific model and serviceability, this may require the replacement of the entire Header Control Unit.
Clear fault codes
After completing the repairs, reconnect the battery and clear the fault codes using a diagnostic scanner or through the machine's onboard diagnostic system.
Recalibrate system
If the CONTOUR MASTER™ Angle Sensor or Header Control Unit was replaced, a calibration of the CONTOUR MASTER™ system must be performed.
Parts you might need
(9)CONTOUR MASTER™ Angle Sensor / Tilt Sensor
BH80936Attachment for Automatic Header Height Sensing
Engine Speed Control Motor Angle Sensor
4257164May be applicable in some contexts
Header Height Sensor
AH170968Sensor and Mountings
- Header Height SensorAH166500
Header Height Sensor
Header Height Sensor Assembly
AH214782Automatic Header Height Control Sensor Assembly
Header Height Sensor Kit
BXE11092Automatic Header Height Control Sensor Kit
Voltage Regulator
AM143359General John Deere voltage regulator; may not be specific to this application
Voltage Regulator
HE191-1748General John Deere voltage regulator; may not be specific to this application
Header Raise Pressure Sensor
No specific OEM part number found in research
Get help to fix this fault by requesting a quote