001231.14

John Deere 001231.14 – TMA / XMA: Steering CAN Bus Communication Failure

Issue description

This fault code indicates a communication breakdown on the CAN bus network related to the steering system. It is triggered when the primary steering control module loses communication with other essential controllers on the dedicated steering CAN bus.

Applies to these machines

  • 8235R
  • 8245R
  • 8260R
  • 8270R
  • 8285R
  • 8295R
  • 8310R
  • 8320R
  • 8335R
  • 8345R
  • 8360R
  • 8400R
  • 8310RT
  • 8335RT
  • 8360RT
  • 9470RT
  • 9520RT
  • 9570RT

Check the cause

  1. Visually inspect the wiring harness and connectors associated with the steering CAN bus for any visible damage, chafing, corrosion, or loose pins

  2. With the machine's power off, measure the resistance between the CAN High and CAN Low wires at a diagnostic connector to check terminating resistors (approx. 60 ohms indicates intact circuit; 120 ohms indicates a missing/failed resistor; near 0 ohms indicates a short circuit)

  3. With the machine's power on, check CAN bus voltages using a multimeter (CAN High should be 2.5-3.5 volts; CAN Low should be 1.5-2.5 volts). Incorrect voltages can indicate a short to power or ground in the wiring or a faulty controller

  4. Perform a wiggle test on the wiring harness and connectors while monitoring CAN bus voltages or using a diagnostic tool to pinpoint intermittent connections

Repair steps

  1. Isolate the fault

    If resistance and voltage checks indicate a problem, disconnect controllers from the steering CAN bus one at a time to see if the correct readings are restored. This helps identify a faulty controller or a wiring issue in a specific branch.

  2. Repair wiring

    If a wiring issue is found (e.g., a short, open circuit, or corroded connector), repair or replace the damaged section of the harness.

  3. Replace terminating resistor

    If a terminating resistor is identified as missing or failed during the resistance check (reading 120 ohms), replace it.

  4. Replace steering control module

    If all wiring and other components on the bus test correctly, the TMA or XMA controller itself may be at fault. Have a certified John Deere technician confirm the diagnosis using specialized diagnostic tools before replacing the module.

  5. Restart and re-check

    After any repair, perform a cold boot of the system by disconnecting power completely for a short period, then restart the tractor and check if the fault code returns.

Parts you might need

(3)
  • Fits a wide range of 8R, 8RT, 9R, and 9RT models. Also available as remanufactured part RM100537.

  • Steering Control Unit

    RE255851

    Listed for various 8RT and 9T series tractors.

  • Replaces RE231728. Fits some older 8000 and 9000 series tractors.

Get help to fix this fault by requesting a quote