1505
John Deere 1505: Manual Rate Adjust Calibration Fault
Issue description
The potentiometer was calibrated in the wrong direction or the difference between the two calibration endpoints is less than 2.00 volts. This error code is only displayed during a calibration fault and is not stored.
Check the cause
The potentiometer calibration direction
The voltage difference between the two calibration endpoints
Repair steps
Verify the calibration direction of the potentiometer
Ensure the potentiometer was calibrated in the correct direction as specified in the service manual.
Measure the voltage difference between the two calibration endpoints
Check that the voltage difference is at least 2.00 volts. If not, recalibrate the potentiometer.