John Deere 1511 – Cornerpost: Missing Grain Loss CAN Message
Issue description
The Cornerpost Control Unit (C03) has not received an expected CAN bus message from the Right Control Unit (E02/RCU) related to the grain loss monitoring system. This communication breakdown prevents the proper monitoring and control of grain loss during agricultural operations.
Applies to these machines
13 machines- 9540 WTS
- 9560 WTS
- 9580 WTS
- 9640 WTS
- 9660 WTS
- 9680 WTS
- 9560 STS
- 9660 STS
- 9760 STS
- 9860 STS
- CTS
- 9650 STS
- 9750 STS
Check the cause
Check for other active or stored Diagnostic Trouble Codes (DTCs), especially CAN bus codes ending in .09, power supply issues to the control units, or specific faults with the Right Control Unit (such as E02 639 09 3)
Inspect the wiring harness and connectors between the Cornerpost Control Unit and the Right Control Unit for chafing, corrosion, or loose connections
Verify the Right Control Unit is receiving a 12-volt supply and has a solid ground connection
Check CAN Bus voltages with the key on and network idle; CAN High and CAN Low should each measure approximately 2.5 volts
Use the onboard diagnostic mode through the cornerpost display to verify if CAN bus messages from the Right Control Unit (E02) are being received (display shows 1 if received, 0 if not)
Repair steps
Address other fault codes
Diagnose and repair any other present fault codes first, as they may be the root cause of the communication issue.
Repair wiring and connectors
Repair or replace any damaged wiring or connectors found during inspection. Clean, secure, and reseat connectors to resolve potential intermittent issues.
Power cycle the system
Turn the key switch to the OFF position, wait at least 30 seconds for controllers to power down completely, and restart the machine to reset the controller.
Update software
Use a John Deere service tool to check for and apply any available software updates for the control modules.
Isolate faulty controller
Disconnect other controllers on the same CAN bus one at a time to determine if a different faulty module is disrupting the network.
Replace Right Control Unit
If all diagnostics point to an internal failure, or if the controller cannot exit its boot block program, replace the Right Control Unit.
Parts you might need
(6)- Right Control UnitAH220395
Compatible with various STS combines (9560, 9660, 9670, 9860, 9870). Verify by serial number.
Right Control Unit
AXE66870Alternate part number for the Right Control Unit.
- Right Control UnitAXE22469
Alternate part number for the Right Control Unit.
- Central Electronic Control UnitAH220602
Compatible with a broad range of WTS and STS combines.
Remanufactured version of AH220602.
Wiring Harnesses and Connectors
Specific to machine model and harness section; consult official parts catalog.