1511
John Deere 1511: CAN Bus Message Missing from Right Control Unit - Grain Loss
Issue description
The system has detected that a CAN Bus message from the Right Control Unit related to Grain Loss is missing. This may affect the proper monitoring and control of grain loss during agricultural operations.
Check the cause
The communication link between the Right Control Unit and the system
The integrity of the CAN Bus wiring connected to the Right Control Unit
The functionality of the Right Control Unit itself
Repair steps
Inspect
Check the CAN Bus wiring for damage, loose connections, or corrosion.
Test
Use a diagnostic tool to verify communication between the Right Control Unit and the system.
Replace
If the Right Control Unit is found to be faulty, replace it with a compatible unit.
Parts you might need
(0)Get help to fix this fault by requesting a quote