John Deere 1529: Accumulator Shutoff Valve Driver Fault
Issue description
The Accumulator Shutoff Valve driver has detected an open, short, over voltage, or over temperature condition. The Header Control Unit is unable to actuate the Accumulator Shutoff Valve until the fault condition is resolved.
Check the cause
Accumulator Shutoff Valve driver circuit
Accumulator Shutoff Valve wiring
Power supply to the Accumulator Shutoff Valve driver
Temperature conditions around the Accumulator Shutoff Valve driver
Voltage levels in the circuit
Repair steps
Inspect
Inspect the Accumulator Shutoff Valve driver circuit for signs of damage, wear, or disconnection.
Test
Test the Accumulator Shutoff Valve wiring for continuity and proper insulation.
Check
Check the power supply to the Accumulator Shutoff Valve driver for correct voltage levels.
Monitor
Monitor the temperature conditions around the Accumulator Shutoff Valve driver to ensure it is within acceptable limits.
Clear
Once the fault condition is resolved, clear the fault code and verify that the Header Control Unit can actuate the Accumulator Shutoff Valve.
Parts you might need