John Deere 1533: HEADERTRAK Return to Cut Sensor Voltage Too High

Issue description

The HEADERTRAK Return to Cut Sensor is reporting a voltage that is greater than 4.5 VDC, which is outside the acceptable range. This indicates a potential issue with the sensor or its wiring.

Check the cause

  1. HEADERTRAK Return to Cut Sensor

  2. wiring connected to the HEADERTRAK Return to Cut Sensor

Repair steps

  1. Inspect

    Inspect the HEADERTRAK Return to Cut Sensor for physical damage or signs of malfunction.

  2. Test

    Test the voltage output of the HEADERTRAK Return to Cut Sensor using a multimeter to confirm the reading exceeds 4.5 VDC.

  3. Check

    Check the wiring and connections associated with the HEADERTRAK Return to Cut Sensor for loose, damaged, or corroded components.