John Deere 1533 – RCU: Feeder House Tilt Sensor Not Calibrated
Issue description
The calibration procedure for the feeder house lateral tilt sensor (also known as the angle sensor) has not been performed or has failed. This sensor is critical for the proper operation of automatic header tilt functions such as Contour Master. When this code is active, the system cannot accurately read the tilt angle of the feeder house, resulting in improper header positioning relative to the ground. The fault can also be triggered if the sensor's voltage readings fall outside the expected range during operation or calibration.
Applies to these machines
24 machines- S550
- S660
- S670
- S680
- S690
- 9470 STS
- 9570 STS
- 9670 STS
- 9770 STS
- 9870 STS
- 9540 WTS
- 9560 WTS
- 9580 WTS
- 9640 WTS
- 9660 WTS
- 9680 WTS
- T550
- T560
- T660
- T670
- W540
- W550
- W650
- W660
Check the cause
Verify the combine is parked on a hard, level surface before starting any calibration procedures
Visually inspect the feeder house tilt sensor, its linkage, and wiring harness for physical damage, looseness, or material buildup
Ensure the sensor wiring harness is securely connected
Check for other active fault codes related to the tilt sensor, such as out-of-range voltage warnings (greater than 4.5V or less than 0.5V)
Access diagnostic addresses on the combine's display to view live voltage readings from the tilt sensor (expected operating range is 0.5 to 4.5 volts)
Repair steps
Prepare for calibration
Start the combine and fully raise the feeder house.
Enter calibration mode
Access the calibration menu through the combine's display (CommandCenter or triple display tachometer) by pressing a calibration or diagnostic switch, then navigate to the feeder house tilt ('tiLt') or fore/aft tilt calibration option.
Establish left and right limits
Follow the on-screen prompts. Use the lateral tilt switch to move the feeder house fully to the left and hold it to store the left limit. Repeat this process for the right side.
Establish center position
Use the tilt switch to visually level the feeder house. Utilize the manual indicator on the feeder house to help find the approximate level position.
Save calibration
Press the appropriate switch to save the calibration values. An 'EOC' (End of Calibration) or similar message will appear if successful. If calibration fails, proceed to sensor replacement.
Prepare for sensor replacement
If calibration repeatedly fails, park the machine safely, lower all equipment, shut off the engine, and disconnect the battery. Remove the left-hand feeder house access shields.
Replace tilt sensor
Disconnect the electrical connector from the sensor. Unbolt the sensor and its associated bracket or linkage. Install the new sensor and reconnect the linkage and electrical connector.
Reassemble and recalibrate
Reinstall any removed shields. You must perform the Feeder House Tilt Calibration procedure (Steps 1-5) again, as it is mandatory after replacing the sensor.
Parts you might need
(4)- Tilt SensorH215397
Primary replacement sensor compatible with STS, S, W, and T series combines
Lateral Tilt Feederhouse Sensor Kit
BXE10759Includes sensor-related components and hardware; compatible with 600-series cutting platforms
- LinkageAH226146
Feeder house tilt sensor linkage
Feeder House Position Sensor Lever
H227696Lever for the position sensor
Get help to fix this fault by requesting a quote