1535

John Deere 1535 – HCU (E01 / LC1): Right Stubble Height Sensor Voltage Too Low

Issue description

The Right Stubble Height Sensor is reporting a voltage that is below the acceptable minimum threshold of 0.5 VDC. This condition indicates a fault with the sensor itself, a short circuit to ground in the signal wire, or an issue with the 5V reference power supply circuit provided by the Header Control Unit.

Applies to these machines

  • 9540 WTS
  • 9560 WTS
  • 9580 WTS
  • 9640 WTS
  • 9660 WTS
  • 9680 WTS
  • 9780 CTS
  • S670
  • S680
  • 9560 STS
  • 9670 STS
  • 9770 STS

Check the cause

  1. Access the combine's diagnostic menu to view the live voltage reading from the right header height sensor (normal is 0.5 to 4.5 VDC)

  2. Inspect the wiring harness and connectors leading to the right stubble height sensor and Header Control Unit for breaks, chafing, or corrosion

  3. Check for a short circuit to ground in the sensor's signal wire

  4. Check the 5V reference power supply from the Header Control Unit (look for accompanying sensor supply voltage fault codes)

  5. Attempt a header height calibration to rule out software or calibration issues

Repair steps

  1. Access the sensor

    Locate the right stubble height sensor on the combine header. The exact position varies depending on the header model.

  2. Test sensor power and ground

    Disconnect the sensor from the harness. Using a multimeter, check for 5V power and a good ground at the harness connector coming from the combine. If missing, the wiring harness or Header Control Unit is likely at fault.

  3. Replace the sensor

    If 5V power and ground are present but the sensor voltage remains below 0.5 VDC, replace the faulty right stubble height sensor.

  4. Clear fault codes

    After completing the repair, use the combine's diagnostic display to clear the diagnostic trouble codes from the Header Control Unit.

  5. Calibrate the system

    Perform a full header height calibration procedure as outlined in the combine's operator's manual to ensure the new sensor provides accurate readings.

Parts you might need

(4)

Get help to fix this fault by requesting a quote

Browse other John Deere codes