John Deere 1535 – Header Control Unit: Right Stubble Height Sensor Voltage Too High
Issue description
The Right Stubble Height Sensor (circuit code 454) is reporting a voltage to the Header Control Unit that exceeds 4.5 VDC. This indicates a potential fault with the sensor itself or a short circuit to a power source in the associated wiring, which disrupts the HeaderTrak™ automatic header height control system.
Applies to these machines
25 machines- 9540
- 9560
- 9580
- 9640
- 9660
- 9680
- 9560 STS
- 9570 STS
- 9650 STS
- 9660 STS
- 9670 STS
- 9750 STS
- 9760 STS
- 9770 STS
- 9860 STS
- 9870 STS
- S550
- S660
- S670
- S680
- S690
- CTS
- 600R
- 600F
- 600FD
Check the cause
Visually inspect the right-hand stubble height sensor, linkage, and wiring harness for physical damage, corrosion, or material buildup. Ensure the sensor arm and linkage can move freely without binding.
Verify that the wiring harness is securely connected to the sensor and that the main feeder house-to-header connector is properly seated.
Use the combine's diagnostic system on the cornerpost display (e.g., LC1 Diagnostic Address 24 on S-Series) to view the live voltage from the right header height sensor (cc# 454). Manually move the header or sensor linkage to see if the voltage changes appropriately or remains static at a high value.
Inspect the wiring harness for a short circuit to a power source. Check the Height Sensor Power circuit (cc# 481), which should measure between 4.75 and 5.25 VDC.
Repair steps
De-energize the system
Turn off the combine and disconnect the battery before beginning any electrical repairs.
Access the sensor
The stubble height sensors are located on the left and right sides of the header.
Disconnect and remove
Disconnect the electrical connector from the sensor. Unbolt the sensor and its associated linkage from the header frame.
Install new sensor
Mount the new sensor and connect the linkage. Ensure all fasteners are torqued to the manufacturer's specification.
Reconnect and test
Reconnect the electrical harness to the new sensor. Reconnect the battery.
Clear fault codes
Access the diagnostic menu, view the active codes, and use the 'CLr?' function to clear the 1535.03 fault. Note that some priority 1 codes may not clear until the underlying issue is resolved.
Perform calibration
Perform a header calibration procedure through the combine's display to teach the control unit the sensor's voltage range from the lowest to the highest position. The calibration process involves moving the header to specific positions as prompted. Failure to calibrate can result in new error codes (e.g., ER72 - voltage greater than 4.5V) and improper operation.
Parts you might need
(2)- Rotary Position SensorAH145352
Listed for numerous STS and S-Series combines, including 9570 STS, 9650 STS, 9670 STS, S660, S670, and S680. Also listed as a cross-reference for aftermarket part AXE58085.
- Header Height SensorAH166500
Listed for 600 series cutting platforms.
Get help to fix this fault by requesting a quote