1536
John Deere 1536: Center Stubble Height Sensor Voltage Too High
Issue description
The Center Stubble Height Sensor (cc# 414) is reporting a voltage that is greater than 4.5 VDC, which is outside the normal operating range. This may indicate a faulty device or an issue with the wiring associated with the sensor.
Check the cause
Center Stubble Height Sensor (cc# 414)
wiring connected to the Center Stubble Height Sensor (cc# 414)
Repair steps
Inspect
Inspect the Center Stubble Height Sensor (cc# 414) for physical damage or signs of malfunction.
Test
Test the voltage output of the Center Stubble Height Sensor (cc# 414) to confirm it is exceeding 4.5 VDC.
Examine
Examine the wiring connected to the Center Stubble Height Sensor (cc# 414) for damage, loose connections, or short circuits.
Parts you might need
(0)Get help to fix this fault by requesting a quote