John Deere 1548.03 – ATC: Outlet Air Temperature Sensor Circuit Voltage High
Issue description
The ClimaTrak™ controller is measuring a voltage exceeding 5 volts (or greater than 4.8 VDC) at the signal input of the sending unit. This high voltage indicates that the sensor's resistance is reading greater than 60KΩ (which would equate to -22°F or -30°C), meaning the circuit is either shorted to a power supply lead or is completely open. When this code is active, the controller restricts automatic temperature control and adjusts the water valve based on a default difference between actual and desired temperatures.
Applies to these machines
25 machines- 6110R
- 6120R
- 6130R
- 6145R
- 6155R
- 6175R
- 6195R
- 6215R
- 6020 to 6920 series
- 6120L to 6520L series
- 7715
- 7815
- 7720
- 7820
- 7920
- 8120-8520 series
- 8130-8530 series
- 8230T-8430T
- 8RT series (8310RT, 8335RT, 8360RT)
- 9030 series
- 9560 STS
- 9660 STS
- 9760 STS
- 9860 STS
- 9660 CTS
Check the cause
Cycle the power by restarting the engine to verify if the active Service Code reappears, as communication messages can sometimes trigger a false code.
Inspect the wiring harness and connections leading to the sending unit (Component B128) for pinched wires, rubbed insulation, or disconnected plugs.
Use a multimeter to check the B128 circuit for an open circuit or a short to a power supply lead.
Measure the resistance of the sensor itself. If it reads greater than 60K Ohms at normal ambient temperatures, the sensor has failed internally.
Repair steps
Access the HVAC Unit
Locate the evaporator housing/HVAC unit (typically located in the cab roof or under the seat depending on the specific machine model).
Locate the Sensor
Find the "Sending Unit for Actual Outlet Air Temperature" (Component ID: B128).
Disconnect and Remove
Unplug the electrical connector from the B128 sensor. Remove the sensor from the air distribution housing.
Install the New Sensor
Insert the replacement sensor into the housing and secure it.
Reconnect
Plug the wiring harness back into the sensor.
Clear Codes
Turn the key on, access the CommandCenter or diagnostic display, and clear the stored ATC 001548.03 code. Run the ClimaTrak system to ensure the code does not return and the air temperature regulates properly.
Parts you might need
(1)Outlet Air Temperature Sensor
Component Identifier: B128. A specific John Deere OEM part number was not explicitly listed, but your local John Deere dealer can pull the exact part using the B128 component ID and your machine's serial number.
Get help to fix this fault by requesting a quote