000158.01

John Deere 000158.01: Main Control Module Has Noted A Low Module Switched 12 Volt Supply Voltage

Issue description

The Main Control Module has detected a low voltage level in the switched 12-volt supply. This may affect the proper operation of the module and related systems.

Check the cause

  1. The power supply to the Main Control Module

  2. Connections and wiring related to the switched 12-volt supply

  3. The voltage level at the Main Control Module

Repair steps

  1. Verify the voltage level at the Main Control Module

    Use a multimeter to measure the voltage at the Main Control Module's power input.

  2. Inspect the wiring and connections

    Check for loose, damaged, or corroded connections in the circuit supplying the switched 12-volt power.

  3. Check the power source

    Ensure that the power source providing the switched 12-volt supply is functioning correctly.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other John Deere codes