John Deere 000158.03: Voltage to Module Exceeds 16 Volts
Issue description
The system has detected a voltage level to the module that exceeds 16 volts. This condition may involve either the Cab Module (AIC) or the Arm Rest Module (AIC), depending on the configuration.
Check the cause
Voltage supply to the module
Connections to the Cab Module (AIC)
Connections to the Arm Rest Module (AIC)
Repair steps
Verify voltage levels
Use a multimeter to measure the voltage supplied to the module. Ensure it does not exceed 16 volts.
Inspect wiring and connections
Check all wiring and connections related to the Cab Module (AIC) and Arm Rest Module (AIC) for damage, corrosion, or loose contacts.
Check for electrical interference
Ensure there is no electrical interference or short circuits affecting the module's power supply.
Parts you might need
(0)Get help to fix this fault by requesting a quote