1638.02

John Deere 1638.02 – HCC / HCU, SCU, SCO: Calibration Fault / Hydraulic Oil Temperature Low

Issue description

Generated when an operator or technician attempts to calibrate the hitch or hydraulic control unit while the tractor's hydraulic oil temperature is below the required threshold.

Applies to these machines

  • 6110M
  • 6120M
  • 6130M
  • 6145M
  • 6155M
  • 6175M
  • 6195M
  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 5090M
  • 5100M
  • 5100MH
  • 5100ML
  • 5115M
  • 5065M
  • 5075M
  • 5085M
  • 5115ML
  • 5095M
  • 5095MH
  • 5105M
  • 5015ML
  • 9230
  • 9330
  • 9430
  • 9530
  • 9630

Check the cause

  1. Verify actual oil temperature using the tractor's display monitor or a diagnostic tool

  2. Perform a sensor sanity check: if the tractor has been working under heavy load but the sensor still reads below 50°C (122°F), the hydraulic oil temperature sensor or its wiring circuit may be faulty

Repair steps

  1. Warm Up the Hydraulic System

    Start the tractor and operate the hydraulic functions (e.g., cycling the loader, dead-heading a remote valve briefly, or driving the tractor) to build heat in the hydraulic oil.

  2. Monitor Temperature

    Watch the temperature readout until the hydraulic oil exceeds 50°C (122°F).

  3. Recalibrate

    Once the oil is within the correct temperature range, restart the Hitch Control Unit (HCC) calibration process.

  4. Inspect Sensor

    If the oil is physically hot but the calibration still fails due to this code, locate the hydraulic oil temperature sensor on the transmission/hydraulic housing. Inspect the wiring harness for damage, and replace the sensor if it is reading out of range.

Parts you might need

(1)
  • Transmission / Hydraulic Oil Temperature Sensor

    OEM part numbers vary heavily depending on the exact tractor series (e.g., RE52722, AL178071, etc.).

Get help to fix this fault by requesting a quote

Browse other John Deere codes