John Deere 170.04 – ATC: Inside Air Temperature Sensor Voltage Too Low

Issue description

The controller measures below 0 volts (or less than 0.1 VDC) at the signal input of the inside air temperature sending unit (sensor B127). This indicates a short to ground in the circuit, or that the sensor's internal resistance has dropped below 50-52 ohms. Automatic temperature control is restricted, and the system may default to using the actual outlet air temperature sensor instead.

Applies to these machines

  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 6000 series
  • 6120-6420
  • 7000 series
  • 7720-7920
  • 8000 series
  • 8130-8530
  • 9000 series
  • 9330-9630
  • R/RT series
  • STS series
  • WTS series
  • 9450
  • 9550
  • 9650 STS
  • 9750 STS
  • Sprayers
  • Forage Harvesters

Check the cause

  1. Locate Sensor B127 (inside air temperature sensor), often located behind the training seat or in the cab roof/duct area.

  2. Inspect the wiring harness (specifically lead 2007) and the sensor connector for damaged insulation, pinched wires, or corrosion that could cause a short to ground.

  3. Use a multimeter to measure the voltage at the sensor's input. A reading consistently below 0.1 VDC confirms a short to ground.

  4. Disconnect the sensor and measure its resistance. If the resistance is less than 50 ohms, the sensor is internally shorted and defective.

Repair steps

  1. Turn off power

    Turn off the machine's engine and electrical power.

  2. Access sensor

    Access the B127 Cab Temperature Sensor. Ensure it is not covered by debris or aftermarket cab accessories, which can sometimes cause erratic readings.

  3. Disconnect harness

    Disconnect the wiring harness from the sensor.

  4. Remove sensor

    If the diagnostic tests proved the wiring is intact but the sensor is shorted, remove the faulty sensor from its mounting bracket.

  5. Install new sensor

    Install the new OEM replacement sensor and securely reconnect the wiring harness.

  6. Clear codes

    Turn the machine's power back on and clear the stored ATC codes via the CommandCenter or diagnostic switch.

  7. Verify repair

    Run the HVAC system in 'AUTO' mode to verify that the cab temperature regulates correctly and the code does not return.