170

John Deere 170 – ATC: Climatrac Cab Air Temperature Sensor Voltage Too Low

Issue description

The Automatic Temperature Control (ATC) unit has detected that the voltage from the cab air temperature sensor is below the normal operating range (less than 0.10 VDC). This typically indicates a short to ground in the sensor's circuit or an internal failure of the sensor itself. The ClimaTrak system relies on this sensor to measure the air temperature inside the operator's cab to automatically regulate heating and cooling output.

Applies to these machines

  • 6020 to 6920S Series
  • 7720
  • 7820
  • 7920
  • 8120
  • 8220
  • 8320
  • 8420
  • 8520
  • 8230T
  • 8330T
  • 8430T
  • 9230
  • 9330
  • 9430
  • 9530
  • 9630

Check the cause

  1. Inspect the cab recirculation air filter and the air conditioning condenser at the front of the tractor to ensure they are clean and free of debris

  2. Locate the cab temperature sensor (typically behind the instructional seat) and ensure it is not covered or obstructed

  3. Inspect the wiring harness and connector pins at the sensor for chafing, breaks, corrosion, or signs of a short to ground

  4. Test the sensor (thermistor) with a multimeter set to Ohms. Measure resistance at room temperature, then warm it (e.g., with a hairdryer) to verify the resistance changes. If it reads open, shorted, or does not change, the sensor is faulty

Repair steps

  1. Prepare machine

    Park the machine on a level surface, shut down the engine, and remove the key.

  2. Access the sensor

    Locate the cab air temperature sensor behind the passenger or instructional seat. Remove any necessary panels or the seat itself to gain access.

  3. Remove faulty sensor

    Carefully disconnect the electrical connector. Remove any clips or screws holding the sensor in place and extract the old sensor.

  4. Install new sensor

    Install the new temperature sensor and securely fasten it in its original position. Reconnect the electrical connector.

  5. Reassemble components

    Reinstall any panels or the seat that were removed during the access step.

  6. Verify repair

    Start the tractor and operate the ClimaTrak system. Clear the diagnostic trouble codes using the tractor's display or service tool if necessary, and verify the fault code does not return. If it returns, further diagnosis of the wiring harness and ATC unit is required.

Parts you might need

(2)
  • Compatible with 7020, 8020, and 8030 series tractors. Verify fitment by serial number.

  • Compatible with various 7R and 8R series tractors. Verify fitment by serial number.

Get help to fix this fault by requesting a quote

Browse other John Deere codes