John Deere 1865.19 – CCU: Incorrect CAN Bus Message, Information from OIC Control Software.
Issue description
This code indicates a data transfer problem on the machine's Controller Area Network (CAN Bus). Specifically, there is an intermittent, corrupted, or non-existent reception of messages that are supposed to be transmitted by the OIC (Operator Interface Control / Cab Module).
Applies to these machines
24 machines- 6110M
- 6120M
- 6130M
- 6145M
- 6155M
- 6175M
- 6195M
- 6090MC
- 6100MC
- 6110MC
- 6090RC
- 6100RC
- 6110RC
- 6110R
- 6120R
- 6130R
- 6145R
- 6155R
- 6175R
- 6195R
- 6215R
- 5085M
- 5100M
- 5115M
Check the cause
Inspect CAN Bus wiring harnesses and connectors between the OIC (Cab) and the CCU (Chassis) for damage, loose pins, or corrosion.
Use a multimeter or diagnostic tool to test for open circuits or short circuits in the CAN Bus lines.
Verify that the CAN Bus terminating resistors are properly installed and test within the correct resistance specifications (typically 60 ohms across the bus).
Check for sources of electrical interference and ensure proper grounding and shielding of the CAN Bus cables.
Check for accompanying codes (such as OIC 520870.02 - Control Software Internal Fault) which would indicate the cab module itself has failed and stopped broadcasting.
Use a diagnostic tool (like John Deere Service ADVISOR or Jaltest) to monitor live CAN Bus messages and verify if the CCU is receiving any data from the OIC.
Repair steps
Module Reset
Perform a hard reset of the OIC and CCU control modules to clear the error and see if the communication fault is a temporary glitch.
Wiring Repair
If open or short circuits were found during diagnostics, repair or replace the damaged sections of the CAN Bus communication harness between the cab and the chassis.
Resistor Replacement
Replace any faulty CAN Bus terminating resistors.
Software Update
Flash/install the latest software updates or patches for both the OIC and CCU control software, as outdated software can cause communication drops.
Module Replacement
If the wiring, resistors, and software are all verified good, but the OIC is still failing to broadcast messages to the CCU, the OIC module must be replaced. If the CCU is failing to receive messages from multiple modules (not just the OIC), the CCU itself may require replacement.
Parts you might need
(9)Chassis Control Unit (CCU) / Main Control Module
AL224162Fits various 6M, 6R, and 7R series tractors. Requires dealer programming/calibration after installation.
Chassis Control Unit (CCU) / Main Control Module
AL216413Fits various 6M, 6R, and 7R series tractors. Requires dealer programming/calibration after installation.
Chassis Control Unit (CCU) / Main Control Module
AL226812Fits various 6M, 6R, and 7R series tractors. Requires dealer programming/calibration after installation.
Chassis Control Unit (CCU) / Main Control Module
AL223636Fits various 6M, 6R, and 7R series tractors. Requires dealer programming/calibration after installation.
Chassis Control Unit (CCU) / Main Control Module
AL206359Fits various 6M, 6R, and 7R series tractors. Requires dealer programming/calibration after installation.
Chassis Control Unit (CCU) / Main Control Module
AN206616Fits various 6M, 6R, and 7R series tractors. Requires dealer programming/calibration after installation.
Chassis Control Unit (CCU) / Main Control Module
LW11896485Fits various 6M, 6R, and 7R series tractors. Requires dealer programming/calibration after installation.
OIC Control Module / Cab Interface ECU
Specific OEM part numbers for the OIC depend entirely on the cab's option package and display configuration.
CAN Bus Terminating Resistor / Communication Wiring Harness
Get help to fix this fault by requesting a quote