000190.18

John Deere 000190.18: Engine Speed Not Received On CAN BUS From Engine Module

Issue description

The Main Control Module has detected that it has not received the engine speed signal on the CAN BUS from the Engine Module. This indicates a communication issue between the two modules.

Check the cause

  1. The connection between the Engine Module and the Main Control Module

  2. The CAN BUS wiring and integrity

  3. The Engine Module for proper operation

Repair steps

  1. Inspect

    Inspect the wiring and connectors between the Engine Module and the Main Control Module for damage, corrosion, or loose connections.

  2. Test

    Test the CAN BUS for proper signal integrity using a diagnostic tool or oscilloscope.

  3. Verify

    Verify the Engine Module is functioning correctly and transmitting the engine speed signal.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other John Deere codes