John Deere 000190.18: Engine Speed Not Received On CAN BUS From Engine Module
Issue description
The Main Control Module has detected that it has not received the engine speed signal on the CAN BUS from the Engine Module. This indicates a communication issue between the two modules.
Check the cause
The connection between the Engine Module and the Main Control Module
The CAN BUS wiring and integrity
The Engine Module for proper operation
Repair steps
Inspect
Inspect the wiring and connectors between the Engine Module and the Main Control Module for damage, corrosion, or loose connections.
Test
Test the CAN BUS for proper signal integrity using a diagnostic tool or oscilloscope.
Verify
Verify the Engine Module is functioning correctly and transmitting the engine speed signal.
Parts you might need