000191.11
John Deere 000191.11: Transmission Output Speed Sensor Signal Discrepancy
Issue description
The system has detected a discrepancy in the signal from the Transmission Output Speed Sensor. This issue is associated with the Transmission Module IVT (PTA).
Check the cause
The Transmission Output Speed Sensor
The Transmission Module IVT (PTA)
Wiring and connections related to the Transmission Output Speed Sensor and Transmission Module IVT (PTA)
Repair steps
Inspect
Inspect the Transmission Output Speed Sensor for damage or misalignment.
Check
Check the wiring and connections between the Transmission Output Speed Sensor and the Transmission Module IVT (PTA).
Test
Test the Transmission Module IVT (PTA) for proper operation.
Parts you might need
(0)Get help to fix this fault by requesting a quote