200017

John Deere 200017 – Armrest Control Unit: Cornerpost CAN Message Missing

Issue description

The system has detected that CAN Bus messages from the Cornerpost Control Unit (C03) are missing. This indicates a communication or data transmission failure on the Controller Area Network (CAN bus). When messages from the Cornerpost Control Unit are not received by other modules on the network, this fault code is logged, which can disrupt the display of critical machine information and affect the functionality of various systems.

Applies to these machines

  • 9540 WTS
  • 9560 WTS
  • 9580 WTS
  • 9640 WTS
  • 9660 WTS
  • 9680 WTS
  • 9560 STS
  • 9650 STS
  • 9660 STS
  • 9750 STS
  • 9760 STS
  • 9860 STS
  • 9780 CTS

Check the cause

  1. Access and record all Diagnostic Trouble Codes (DTCs) from all control units (ALL address) using the diagnostic display by turning the key to the 'RUN' position and pressing a diagnostic switch to determine if the communication issue is isolated or part of a wider problem

  2. Perform a controller 'Roll Call' on the GreenStar or VISIONTRAK display to see if the Cornerpost Control Unit (C03) is actively communicating (message count increasing)

  3. Visually inspect the wiring harness to the corner post for any signs of damage, chafing, pinching, or corrosion

  4. Disconnect, inspect, and reconnect the main electrical connectors to the Cornerpost Control Unit (e.g., connector X500) and the ribbon cables connecting the main circuit board to individual display modules

  5. Verify that the Cornerpost Control Unit is receiving correct voltage (typically 12V) and has a solid ground connection

  6. Check CAN bus integrity with the system powered off by measuring resistance across CAN High and CAN Low wires (should be approximately 60 Ohms; 120 Ohms indicates a missing terminating resistor)

  7. Check CAN bus voltage with the system powered on (CAN High and CAN Low should both show approximately 2.5 volts in a steady state)

Repair steps

  1. Address other active fault codes

    Resolve any other active Priority 1 or 2 fault codes first, as they may be the root cause of the communication issue.

  2. Perform a hard reset

    Disconnect the machine's batteries for several minutes to reset all control modules. Reconnect the batteries and check if the fault code returns.

  3. Isolate faulty display modules

    If the fault persists, disconnect individual display modules from the main Cornerpost Control Unit one at a time to see if the fault clears. A faulty display can sometimes disrupt the entire corner post's communication.

  4. Replace Cornerpost Control Unit

    If wiring, power, ground, and connected displays have been ruled out, replace the Cornerpost Control Unit (main circuit board/motherboard). After replacement, reprogram the controller with the latest software if necessary.

Parts you might need

(2)

Get help to fix this fault by requesting a quote

Browse other John Deere codes