200112

John Deere 200112 – E03: 12VDC Not Detected at K7 Relay

Issue description

The system has detected an absence of 12-volt DC power at the output of the Grain Tank Cover Fold relay (K7) when the relay is energized. This indicates a potential failure of the K7 relay itself or an issue within the Control Power circuit (cc# 016).

Applies to these machines

  • 9540
  • 9560
  • 9580
  • 9640
  • 9660
  • 9680
  • 9780
  • 9880
  • 9560 STS
  • 9650 STS
  • 9660 STS
  • 9750 STS
  • 9760 STS

Check the cause

  1. Locate the Control Relay Board (refer to the operator's manual for a diagram on 9660 STS and 9760 STS models) and identify the K7 relay.

  2. Visually inspect the K7 relay and associated wiring for physical damage, corrosion, loose connections, chafing, or breaks.

  3. With the ignition on and grain tank cover fold function activated, use a multimeter to test for 12VDC at the input and output terminals of the K7 relay (voltage should be present at input but absent at output if the fault is active).

  4. Swap the K7 relay with a known good identical relay on the board to determine if the relay itself has failed.

  5. Inspect all related fuses to ensure they are intact, as a blown fuse can interrupt power to the circuit.

  6. After each diagnostic step, clear the fault codes and re-test the system to see if the error returns.

Repair steps

  1. Disconnect power

    Turn off the combine and disconnect the battery to prevent electrical shock before beginning repairs.

  2. Replace K7 relay

    If the K7 relay is identified as the fault (e.g., power at input but not output, or swapping resolves the issue), replace it with a new relay matching OEM specifications.

  3. Repair wiring

    If damage to the Control Power circuit (cc# 016) or the relay's wiring is discovered, repair or replace the affected sections.

  4. Replace blown fuses

    If a blown fuse was found during inspection, replace it with a new one of the identical amperage rating. Do not use a higher rating.

  5. Test system

    Reconnect the battery, start the combine, clear fault codes, and operate the grain tank cover to ensure the issue is resolved and the code does not return.

  6. Seek professional assistance

    If the fault persists after these steps, it may indicate a more complex issue within the Left Control Unit (E03) or other parts of the electrical system. Consult an authorized John Deere dealer.

Parts you might need

(3)
  • RelayRE339779

    General purpose John Deere relay; verify compatibility with machine serial number.

  • Relay

    4236267

    General purpose John Deere relay; verify compatibility with machine serial number.

  • General purpose John Deere relay; verify compatibility with machine serial number.

Get help to fix this fault by requesting a quote

Browse other John Deere codes