200145

John Deere 200145: 12VDC Not Detected on Light Power 3 of Control Relay Board

Issue description

The system has detected that 12VDC is not present on Light Power 3 of the Control Relay Board. This indicates a potential issue with the connection, wiring, or Fuse F3 of the Engine Compartment Relay Panel.

Check the cause

  1. Light Power 3 connection

  2. Wiring related to Light Power 3

  3. Fuse F3 of the Engine Compartment Relay Panel

Repair steps

  1. Inspect

    Inspect the connection for Light Power 3 on the Control Relay Board for looseness, corrosion, or damage.

  2. Test

    Test the wiring associated with Light Power 3 for continuity and proper insulation.

  3. Check

    Check Fuse F3 of the Engine Compartment Relay Panel for proper installation and functionality.

Parts you might need