John Deere 200151 – LC2: Threshing Clearance Failed to Reach Commanded Clearance
Issue description
The threshing clearance system failed to move the concaves to the commanded position within a 30-second timeframe. This indicates a malfunction in the electronic or mechanical components responsible for adjusting the gap between the rotor and the concaves.
Applies to these machines
17 machines- 9540
- 9560
- 9580
- 9640
- 9660
- 9680
- 9560 STS
- 9570 STS
- 9650 STS
- 9660 STS
- 9670 STS
- 9750 STS
- 9760 STS
- 9770 STS
- 9860 STS
- 9870 STS
- 9670
Check the cause
Visually inspect the threshing clearance adjustment mechanism for physical obstructions, debris buildup, or damage that could impede movement
Check the mounting of the threshing clearance position sensor and adjustment actuator for looseness, including broken roll pins or bolts in the linkage that connects the actuator to the concave adjustment tube
Inspect wiring harnesses and connectors leading to the position sensor and adjustment actuator for damage, corrosion, or loose connections
Attempt to run the Threshing Clearance Calibration procedure through the CommandCenter display and note if the system fails to find the fully open or closed positions
Repair steps
Diagnose position sensor
If the threshing clearance calibration fails or produces inconsistent results, the position sensor is likely faulty. You can temporarily swap it with the ContourMaster head sensor (if it shares the same part number) to verify.
Replace position sensor
If the sensor is confirmed faulty (causing erratic readings or loss of position feedback), replace it with a new unit.
Inspect and replace adjustment actuator
If the sensor functions correctly but concaves do not move, listen for the actuator motor when commanded from the cab. If there is no sound, check for a failed motor or lack of power. If the motor runs but concaves do not move, inspect the gearbox and linkage for mechanical failure. Replace the actuator if faulty.
Perform system recalibration
After replacing the sensor or actuator, perform a Threshing Clearance Calibration so the control unit can learn the fully open and closed positions. Ensure no round bar concave covers are installed during this process to avoid an incorrect zero position.
Parts you might need
(3)Fits various STS and WTS combines, including 9560 STS, 9570 STS, 9650 STS, 9660 STS, 9670, 9540, 9560, 9580, 9640, 9660
Used on S-series and STS combines
Used on S-series and STS combines
Get help to fix this fault by requesting a quote