John Deere 200301: Chaffer Position Did Not Reach the Set Point During Automatic Combine Adjust
Issue description
The chaffer position failed to reach the set point during the automatic combine adjust process. This indicates a potential issue with the system's ability to achieve the desired position as intended by the control mechanism.
Check the cause
The chaffer position sensor
The actuation mechanism for the chaffer
The control signal to the chaffer system
Repair steps
Inspect
Inspect the chaffer position sensor for proper installation and functionality.
Test
Test the actuation mechanism for the chaffer to ensure it is operating as intended.
Verify
Verify the control signal to the chaffer system is being sent correctly.
Parts you might need
(0)Get help to fix this fault by requesting a quote