200310

John Deere 200310: Chaffer Limit Switch Activated After Actuator Position Sensor Pulses

Issue description

The Chaffer Limit Switch is activated following 5 pulses from the actuator position sensor. This indicates an unexpected interaction between the actuator position sensor and the Chaffer Limit Switch.

Check the cause

  1. Chaffer Limit Switch

  2. Actuator Position Sensor

  3. Wiring and connections between the Chaffer Limit Switch and the actuator position sensor

Repair steps

  1. Inspect

    Inspect the Chaffer Limit Switch for physical damage or misalignment.

  2. Test

    Test the actuator position sensor for proper operation and signal output.

  3. Check

    Check the wiring and connections between the Chaffer Limit Switch and the actuator position sensor for continuity and proper termination.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other John Deere codes