200316
John Deere 200316: No Pulses from Chaffer Adjust Actuator After Command to OPEN or CLOSE
Issue description
The system detects that no pulses are being received from the Chaffer Adjust Actuator for a duration of 5 seconds following a command to either OPEN or CLOSE. This indicates a potential issue with the actuator's response to control signals.
Check the cause
The Chaffer Adjust Actuator for proper operation
The wiring and connections to the Chaffer Adjust Actuator
The control signal being sent to the Chaffer Adjust Actuator
Repair steps
Inspect
Inspect the Chaffer Adjust Actuator for visible damage or obstruction.
Test
Test the Chaffer Adjust Actuator for proper response to control signals.
Check
Check the wiring and connections to the Chaffer Adjust Actuator for continuity and secure attachment.
Parts you might need
(0)Get help to fix this fault by requesting a quote