200347

John Deere 200347: No Pulses from Sieve Adjust Actuator

Issue description

The system detects that no pulses are being received from the Sieve Adjust Actuator for 30 seconds after a command to open or close is issued. This fault must be cleared before the Sieve Adjust Actuator can be operated.

Check the cause

  1. The Sieve Adjust Actuator

  2. The circuit connected to the Sieve Adjust Actuator

  3. The command signal to the Sieve Adjust Actuator

Repair steps

  1. Verify the command signal to the Sieve Adjust Actuator

    Ensure that the command to open or close is being sent correctly from the control system.

  2. Inspect the connection to the Sieve Adjust Actuator

    Check for loose, damaged, or disconnected wiring related to the Sieve Adjust Actuator.

  3. Test the Sieve Adjust Actuator

    Use diagnostic tools to confirm whether the Sieve Adjust Actuator is receiving and responding to commands.

  4. Clear the fault code

    Once the issue is resolved, clear the fault code using the appropriate diagnostic procedure.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other John Deere codes