John Deere 002005.09 – FCC: CAN BUS Message Fault
Issue description
A fault has been detected in the communication of the CAN BUS message within the Dash Module or Front Chassis Control (FCC) unit. The '.09' suffix denotes an abnormal update rate, meaning messages are not being received in a timely manner. This issue affects the proper exchange of data between systems, indicating the FCC is either not receiving expected messages from other control units or is sending messages that other modules cannot receive or understand.
Applies to these machines
3 machines- 6R
- 7R
- 8R
Check the cause
Visually inspect the wiring harnesses connected to the FCC and other nearby controllers for signs of damage, chafing, corrosion, or loose connections
Check for other active or stored fault codes in other control units, which may point to a more widespread CAN bus network issue
Power cycle the system (turn the machine off and on again) to see if it resolves a temporary communication glitch
Perform a CAN Bus Resistance Check (with power OFF): Measure resistance between CAN high and CAN low wires. A healthy bus reads ~60 ohms. 120 ohms indicates a missing or faulty terminator. Significantly lower indicates a short circuit or controller issue
Perform a CAN Bus Voltage Check (with power ON): Measure voltage of CAN high (typically 2.5-3.0V) and CAN low (typically 2.5-2.0V) relative to a good ground. Abnormal voltages indicate a short to power, short to ground, or faulty controller
Repair steps
Repair wiring
Address any physical wiring issues found during the visual inspection. Repair damaged wires and ensure all connectors are clean and securely fastened.
Replace terminating resistors
If the resistance check shows 120 ohms, locate and inspect the active and passive terminating resistors (often found near the front of the tractor and in the cab area behind the seat). Replace any faulty terminator.
Isolate faulty controller
If resistance and voltage checks indicate a problem but wiring and terminators are in good condition, unplug controllers one by one starting with the FCC. If the fault disappears after unplugging a specific controller, that controller is likely the source of the problem.
Update software
Have a service technician check for and apply any available software updates for the affected controller using appropriate diagnostic tools.
Replace controller
If a controller is identified as the source of the fault and cannot be repaired through software updates or wiring fixes, replace the faulty unit.
Parts you might need
(6)Flex Load Vehicle Controller (FLC)
AT323254Verify correct part number for specific machine model and serial number
Flex Load Vehicle Controller (FLC)
AT305854Fits some D-Series Motor Graders
Verify correct part number for specific machine model and serial number
Right Side Multi-Functional Controller
AT446684Verify correct part number for specific machine model and serial number
Multi-Functional Controller
F686044Verify correct part number for specific machine model and serial number
CAN Bus Terminator
Part numbers vary; common replacement item for CAN bus faults
Get help to fix this fault by requesting a quote