002007.09

John Deere 002007.09 – BLC: CAN BUS PTO Module Message Issue

Issue description

The fault code indicates an internal message issue within the Main Controller (BLC), specifically a communication breakdown with the PTO Module over the CAN BUS network. The Main Controller is not receiving the expected data messages from the PTO module, which typically results in a loss of PTO functionality.

Applies to these machines

  • 6110M
  • 6120M
  • 6130M
  • 6145M
  • 6155M
  • 6175M
  • 6195M

Check the cause

  1. Check the diagnostic display for other active fault codes, especially those related to power supply or other control modules, which could indicate a wider network issue

  2. Inspect fuses related to the PTO and control modules to ensure a module hasn't lost power

  3. Visually inspect the wiring harness and connectors between the PTO module, the main control module, and related components for damage, corrosion, or loose connections

  4. Check CAN BUS voltage with the key on and engine off (CAN High and CAN Low should both read approximately 2.5 volts)

  5. Check CAN BUS resistance with the battery disconnected (should read approximately 60 ohms; a reading of 120 ohms indicates a problem with a terminating resistor)

  6. Restart the tractor to see if a simple power cycle re-establishes communication between the modules

Repair steps

  1. Address related fault codes

    Resolve any other active fault codes first, particularly those affecting power supply or other control modules on the CAN network.

  2. Perform diagnostic checks

    Perform the diagnostic checks listed above.

  3. Isolate the CAN BUS network

    If wiring and connectors appear to be in good condition, disconnect other control modules on the CAN BUS one at a time to see if the fault code disappears. This identifies if another faulty module is disrupting the network.

  4. Test the PTO solenoid

    If CAN BUS communication is verified as intact, test the PTO solenoid for proper operation by checking for a clicking sound when power is applied or by measuring its resistance.

  5. Swap suspected components

    If a faulty module or terminating resistor is suspected, swap the component with a known good unit to confirm the diagnosis before purchasing a replacement.

  6. Consult the Official Service Manual

    Consult the official John Deere technical manual for the specific tractor model or use Operations Center™ PRO Service for detailed diagnostic and repair procedures.

Parts you might need

(7)
  • Listed for various 6M and 6R models. Verify fitment by serial number.

  • Verify fitment by serial number.

  • Verify fitment by serial number.

  • PTO SwitchAL172871

    Electrical Quick Raise Lift Control for various 6M models.

  • PTO Module/Controller

    May be integrated into the Main Control Module or exist as a separate unit depending on the exact machine configuration.

  • PTO Solenoid

    Generic component, verify exact part number with dealer.

  • CAN BUS Terminating Resistor

    Swappable for diagnostic purposes.

Get help to fix this fault by requesting a quote

Browse other John Deere codes