2007.09

John Deere 2007.09 – TIQ: Incorrect CAN BUS Message, Information from RPT Control Software

Issue description

A data transfer problem on the CAN Bus network where the reporting module is failing to receive necessary messages from the RPT control software, forcing the system into a degraded state.

Applies to these machines

  • 6110M
  • 6120M
  • 6130M
  • 6145M
  • 6155M
  • 6175M
  • 6195M
  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 5045E
  • 5055E
  • 5075E
  • 5085M
  • 5100M
  • 5115M
  • 6140M
  • 6140R
  • 6150R
  • 6170R
  • 6190R
  • 6210R
  • 6090MC
  • 6100MC
  • 6110MC
  • 6090RC
  • 6100RC
  • 6110RC
  • 7210R
  • 7230R
  • 7250R
  • 7270R
  • 7290R
  • 8245R
  • 8270R
  • 8295R
  • 8320R
  • 8335R
  • 9470RT
  • 9520RT
  • 9570RT

Check the cause

  1. Inspect CAN Bus wiring for defects, damaged wires, loose connections, or corroded pins between the TIQ and RPT modules

  2. Verify communication using a diagnostic tool (e.g., John Deere Service Advisor or Jaltest) to monitor CAN Bus messages between the TIQ and RPT

  3. Check for electrical interference and ensure proper grounding and shielding of the CAN Bus cables

  4. Assess software health to see if there are software bugs hindering communication or if excessive traffic/conflicts are occurring on the CAN Bus

Repair steps

  1. Reboot the System

    Perform a soft reset or reboot of the control units involved to clear any transient errors or glitches in the system.

  2. Repair Wiring

    If the physical inspection revealed loose, damaged, or corroded wires/connectors between the TIQ and RPT modules, repair or replace the faulty wiring harness sections.

  3. Update Software

    Install any available firmware updates or patches for both the RPT and TIQ control software to resolve known bugs.

  4. Isolate Network Traffic

    If excessive traffic is detected on the CAN Bus, temporarily reduce the number of active devices or reconfigure network settings to isolate the issue.

  5. Test Functionality

    After making necessary repairs or adjustments, conduct thorough testing to ensure that messages are being correctly received by the TIQ and that full machine functionality has been restored.

Parts you might need

(4)
  • TIQ Control Module

    Transmission Regulation System / Cab Module

  • RPT Control Module

    Rear Power Train / Rear Chassis Module

  • CAN Bus Wiring Harness

    Fitment: Varies by chassis length and cab configuration

  • CAN Bus Connectors / Pins

    Fitment: Standard J1939/CAN connectors

Get help to fix this fault by requesting a quote