002007.09

John Deere 002007.09 – VLC: CAN BUS Message Fault in Chassis Module

Issue description

A fault has been detected in the CAN BUS message communication related to the Vehicle Load Center (VLC), also known as the Chassis Module. The .09 suffix signifies a communication error, indicating that the VLC is either not sending messages, not receiving them, or the messages are corrupted on the Controller Area Network (CAN bus).

Applies to these machines

  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 8130
  • 8230
  • 8330
  • 8430
  • 8530
  • 8225R
  • 8335R
  • 9330
  • 9430
  • 9530
  • 9630
  • 9360R
  • 9560R

Check the cause

  1. Visually inspect the wiring harness and connectors associated with the VLC module for signs of damage, chafing, corrosion, pinched wires, or loose connections.

  2. Check the ground points for the VLC and other modules on the CAN bus to ensure they are clean and tight.

  3. Perform a CAN Bus Resistance Check: With the battery disconnected, measure resistance between Pin C (CAN High) and Pin D (CAN Low) at the 9-pin diagnostic connector. Expected reading is approximately 60 Ohms. 120 Ohms indicates a missing terminator or open circuit; 0 Ohms indicates a short circuit; open-loop indicates a break in wiring or both terminators missing.

  4. Perform a CAN Bus Voltage Check: With the battery reconnected and ignition ON (engine off), measure DC voltage between Pin C and ground (Expected: 2.5V to 3.5V) and Pin D and ground (Expected: 1.5V to 2.5V).

Repair steps

  1. Address resistance and voltage issues

    If resistance reads 120 Ohms, locate and inspect the two terminating resistors and their wiring. If resistance is 0 Ohms or voltages are abnormal, unplug modules from the CAN bus one at a time, re-checking readings after each. The last module disconnected before readings normalize is likely the source of the fault.

  2. Isolate the VLC module

    Locate the VLC module (often at the rear of the tractor). Inspect its connectors for damage, corrosion, or pushed-out pins. With the VLC unplugged, check for continuity and shorts to power or ground on the CAN bus wires leading to the module.

  3. Update software and programming

    If the wiring and the module itself appear to be in good condition, perform a software update or reprogram the control unit using a John Deere service tool.

  4. Replace the VLC module

    If all wiring and connections are confirmed to be good, and the fault persists pointing towards an internal failure, replace the Vehicle Load Center (VLC) module.

Parts you might need

(1)

Get help to fix this fault by requesting a quote

Browse other John Deere codes