Issue description

The Instrument Control Unit (ICU) has lost communication with the Automatic Temperature Control (ATC) module over the CAN bus. The '.09' suffix indicates a communication system error where an expected message from the ATC is absent or has timed out. This disruption can be caused by a blown fuse, wiring harness damage, or an internal failure of the ATC module itself.

Applies to these machines

  • 7720
  • 7820
  • 7920
  • 7630
  • 7730
  • 7830
  • 7930
  • 8130
  • 8230
  • 8330
  • 8430
  • 8530
  • 9230
  • 9330
  • 9430
  • 9530
  • 9630
  • 7185J
  • 7195J
  • 7205J
  • 7210J
  • 7225J

Check the cause

  1. Check for other active fault codes to help pinpoint the root cause of the communication error

  2. Restart the tractor to determine if the fault is a temporary communication glitch

  3. Check fuses supplying the modules. For 7020 and 7030 Series, check fuse F42. For general ATC message missing faults, check fuse F6

  4. Visually inspect the CAN bus wiring harness and connectors (especially at the ICU and ATC modules) for chafing, corrosion, or loose connections

  5. With the battery disconnected, measure resistance between CAN High and CAN Low wires (often pins C and D of the diagnostic connector). Approximately 60 ohms indicates intact terminating resistors; around 120 ohms suggests one is missing or faulty

Repair steps

  1. Isolate the ATC module

    If fuses are intact and the fault specifies an ATC message missing, focus diagnostics on the ATC module and its specific wiring.

  2. Test CAN bus voltages

    With the key on and engine off, measure CAN bus voltages to ground. CAN High should be approximately 2.5V to 3.0V, and CAN Low should be 2.0V to 2.5V. Significant deviations indicate a module issue or wiring short.

  3. Perform a wiggle test

    While monitoring the fault code status or CAN voltages with a breakout harness, gently wiggle the wiring harness at connectors and potential rub points to identify intermittent connections.

  4. Disconnect modules sequentially

    If CAN bus resistance is incorrect, unplug modules one at a time. If resistance returns to a normal value (e.g., 120 ohms with one terminator unplugged), the disconnected module or its internal resistor is likely faulty.

  5. Replace faulty components

    Based on diagnostic results, replace the identified faulty component, such as a damaged wiring harness section, a failed terminating resistor, or the ATC control unit.