002035.09

John Deere 002035.09 – ICU: Loss of Communication with HCU

Issue description

The Instrument Cluster Unit (ICU), also referred to as the Cab Module (TIQ), has detected a loss of communication with the Hydraulic Control Unit (HCU) on the CAN bus. The .09 Failure Mode Identifier indicates an abnormal update rate, meaning messages from the HCU are missing or not being received in the expected timeframe. This interrupts information flow between the modules and can lead to hydraulic system malfunctions.

Applies to these machines

  • 9230
  • 9330
  • 9430
  • 9530
  • 9630
  • 6110R
  • 6120R
  • 7200R
  • 7280R
  • 6000 Series
  • 6010 Series
  • 210K
  • 210K EP
  • 316GR
  • 317G
  • 318E
  • 318G
  • 319E
  • 320E
  • 323E
  • 324E
  • 326E
  • 328E
  • 329E
  • 332E
  • 333E
  • 903K
  • 903KH
  • 909K
  • 909KH
  • 953K
  • 959K

Check the cause

  1. Check fuses related to the control units, specifically F30 (HCU power supply), F22, and F35 (ICU/CAB).

  2. Visually inspect the wiring harness and connectors between the ICU and HCU for chafing, corrosion, pinched wires, or loose connections.

  3. Perform a cold boot by shutting down the machine completely and disconnecting the battery for several minutes to reset the controllers.

  4. Measure CAN Bus resistance at the diagnostic connector with the battery disconnected (should be approximately 60 Ohms). 120 Ohms indicates an open circuit or missing terminating resistor; significantly below 60 Ohms indicates a short or faulty controller.

  5. Measure CAN Bus voltages to ground with the key on and engine off. CAN High (Yellow) and CAN Low (Green) should both be approximately 2.5V. Voltages outside the 2.0V to 4.0V range indicate a short or failing transceiver.

Repair steps

  1. Verify HCU power and ground

    Using a multimeter, confirm the HCU is receiving the correct voltage at its power pin and has a solid connection to ground at its ground pin (refer to machine-specific manual for pinouts).

  2. Isolate the faulty module

    If CAN bus resistance or voltage readings are incorrect, unplug controllers from the CAN network one at a time. Re-measure after each; if readings return to normal, the unplugged module is likely the source of the fault.

  3. Test the HCU

    If power and ground are verified and module isolation points to the HCU, the unit itself is the most likely cause of the failure.

  4. Replace the HCU

    Replace the faulty Hydraulic Control Unit with the correct part number for the machine's model and serial number.

  5. Calibrate and program

    Program or calibrate the new HCU using John Deere Service Advisor software to ensure correct communication with other modules.

Parts you might need

(4)
  • Hydraulic Control Unit (HCU)

    AT388818

    Commonly used on 210K, 318E, 317G, 323E, 333E and similar models.

  • Hydraulic Control Unit (HCU)

    AT420507

    Used on 903K, 909K, 953K, and 959K models.

  • Remanufactured part used on 6000/6010 series tractors.

  • Instrument Cluster Unit (ICU/TIQ)

    May require repair or replacement if diagnostic tests point to a failure of the ICU instead of the HCU.