2047.09

John Deere 2047.09 – Multiple: Missing CAN Message / Communication Lost (Abnormal Update Rate)

Issue description

A control module on the machine's CAN bus network has stopped receiving expected data messages from another module (potentially the Front Chassis Module / Suspended Front Axle module, SFA). This is usually caused by a physical wiring issue, a failed terminating resistor, or a malfunctioning control unit.

Applies to these machines

  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 6110M
  • 6120M
  • 6130M
  • 6230
  • 6330
  • 6430
  • 6910S
  • 8245R to 8400R
  • 9470RT
  • 9520RT
  • 9570RT
  • 5085M
  • 5100M
  • 5115M
  • 310J
  • 310SJ
  • 410J
  • 315SK

Check the cause

  1. Inspect the CAN bus network wiring and connectors between the SFA module and the main CAN hub for damage, corrosion, or loose pins.

  2. Verify that the SFA module is receiving proper unswitched and switched ignition voltage. Check related fuses (e.g., F30) and ensure the battery is fully charged.

  3. Perform a CAN Bus Resistance Test with the machine off and battery disconnected. Measure resistance between CAN High and CAN Low pins (60 ohms is normal, 120 ohms indicates one missing/open resistor, OL indicates a complete break).

  4. Perform a CAN Bus Voltage Test with the key ON. CAN High should fluctuate between 2.5V and 3.5V, and CAN Low should fluctuate between 1.5V and 2.5V.

Repair steps

  1. Disconnect Power

    Turn off the ignition and disconnect the negative battery cable to prevent electrical shorts.

  2. Repair Wiring

    If the diagnostic checks revealed broken wires, chafing, or corroded connectors in the CAN harness leading to the SFA module, repair or replace the affected harness sections.

  3. Replace Terminating Resistor

    If the resistance test showed 120 ohms, locate and replace the faulty CAN bus terminating resistor.

  4. Replace the Module

    If the wiring, terminating resistors, and power/ground supplies are all verified as good, but the SFA module still fails to communicate, the SFA control unit has suffered an internal failure and must be replaced.

  5. Reassembly and Clearing Codes

    Reconnect the battery. Turn the key switch to the ON position. Use John Deere Service ADVISOR™ or the Standard Display Monitor (SDM) to clear the stored diagnostic trouble codes.

  6. Operational Checkout

    Start the engine and perform a test drive or operational checkout of the front axle suspension/chassis systems to ensure the code does not return.

Parts you might need

(7)
  • SFA Control Unit (Front Chassis Module / Suspended Front Axle Module)

    AL119257

    Common for 6000/7000 series like 6910S; often available as a Remanufactured part

  • SFA Control Unit

    AL113367

    Alternate/superseded numbers for 6000 series

  • SFA Control Unit

    AL118389

    Alternate/superseded numbers for 6000 series

  • SFA Control Unit

    RE306838

    Fitment for 8R series, e.g., 8345R

  • SFA Control Unit

    SJ30490

    Generic SFA Electronic Control Unit

  • CAN Bus Terminating Resistor

    Generic John Deere electrical part; part number varies heavily by specific chassis harness

  • CAN Bus Wiring Harness / Connectors

    Generic repair pigtails

Get help to fix this fault by requesting a quote

Browse other John Deere codes