John Deere 002049.09 – TIQ: CAN Bus Cab Message Missing
Issue description
A fault has been detected in the CAN BUS communication system indicating that messages from the Cab Module (TIQ) are not being received by other control units on the network within the expected timeframe (abnormal update rate). This communication breakdown can result in a range of symptoms, from non-functional controls to the machine stopping and placing itself in park.
Applies to these machines
23 machines- 7715
- 7815
- 6J Series
- 6145J
- 6165J
- 6180J
- 6205J
- 9x30 Series
- 9230
- 9330
- 9430
- 9530
- 9630
- 6M Series
- 6R Series
- 8x30 Series
- 8130
- 8230
- 8330
- 8430
- 8530
- 9R Series
- 9360R
Check the cause
Check fuses related to the cab and instrument controllers (specifically F22 or F35 depending on the model)
Restart the tractor to see if a power cycle clears an intermittent communication fault
Visually inspect the CAN bus wiring harness for abrasions, pinch points, or sharp bends
Inspect connectors for corrosion (green/white powder), loose pins, or moisture intrusion
With battery disconnected, measure CAN bus resistance between CAN High and CAN Low at a diagnostic connector (should be approximately 60 Ohms)
With key on and engine off, measure CAN bus DC voltage relative to ground (CAN High, typically a yellow wire, and CAN Low, typically a green wire, should both be approximately 2.5 volts)
Repair steps
Check fuses and restart
Check fuses F22 or F35 and restart the tractor to clear potential intermittent faults.
Clean and reseat connectors
Disconnect the battery. Locate connectors for the affected controllers (ICU, ACU, etc.) and major CAN bus connection points in the cab. Clean contacts with a wire brush, apply dielectric grease to protect against moisture, and firmly reseat them.
Test CAN bus resistance
With the battery disconnected, measure resistance between CAN High and CAN Low. A reading of ~120 Ohms indicates a missing terminating resistor or open circuit. A reading near 0 Ohms indicates a short between the wires.
Isolate faulty component
If resistance is incorrect or the fault is intermittent, unplug one CAN bus module at a time. Re-check resistance or restart the machine to see if the fault clears, which will identify the problematic module or harness section.
Replace or repair faulty component
Repair or replace the damaged section of the CAN bus wiring harness, or replace the specific control module identified as the source of the fault.
Program new control unit
If a control unit was replaced, have an authorized John Deere dealer program or calibrate the new module to ensure correct communication on the network.
Parts you might need
(7)For 9630 tractor
- Armrest Control Unit (ACU)RE229376
Verify fitment by serial number
Armrest Control Unit (ACU)
RE71084Verify fitment by serial number
- Electronic Control UnitAL222928
For 6R series tractors
Universal Control Framework (UCF) Controller
PH85238462Verify fitment by serial number
CAN Bus Wiring Harness
Specific to the damaged section and tractor model
CAN Bus Terminating Resistor
May be integrated into a controller or harness connector
Get help to fix this fault by requesting a quote