John Deere ICU002054.09 – ICU: ASU Message Missing

Issue description

The system is reporting that an ASU message is missing. This may be due to a power issue related to the fuses associated with the AutoPowr and PowrQuad Plus systems. If the code persists after restarting the vehicle, professional assistance is required.

Check the cause

  1. Fuses F35 on AutoPowr

  2. Fuses F45 PowrQuad Plus

Repair steps

  1. Check

    Verify the condition of fuses F35 on AutoPowr and F45 PowrQuad Plus.

  2. Restart

    Restart the vehicle to see if the code clears.

  3. Contact

    If the code returns after restarting, contact a John Deere technician as soon as possible.