John Deere 2167.09 – PL4: Incorrect CAN Bus Message, Information from PL2 Control Software
Issue description
There is a data transfer problem between the PL4 control software and the PL2 control software. The reception of messages sent on the CAN Bus by the PL2 module is intermittent or non-existent, typically pointing to an open circuit, a short circuit, or faulty CAN bus terminating resistors.
Applies to these machines
17 machines- 6110R
- 6120R
- 6130R
- 6145R
- 6155R
- 6175R
- 6195R
- 6215R
- 6105R
- 6115R
- 6125R
- 6135R
- 6140R
- 6150R
- 6170R
- 6190R
- 6210R
Check the cause
Visually inspect the transmission wiring harness connecting the PL2 and PL4 modules for chafing, pinch points, melted insulation, or disconnected plugs.
Disconnect the harnesses at the PL2 and PL4 modules and inspect the pins for corrosion, moisture, or push-out.
Use a digital multimeter to test for continuity on the CAN High and CAN Low wires between the PL2 and PL4 connectors, verifying there is no short to ground or short to power.
Measure the resistance across the CAN High and CAN Low pins to verify CAN Bus terminators; it should read approximately 60 ohms.
Ensure that both the PL2 and PL4 control modules are flashed with the latest software versions via John Deere Service Advisor.
Repair steps
Prep the Machine
Park the tractor on a level surface, engage the parking brake, turn off the engine, and disconnect the negative battery cable to prevent electrical shorts during repair.
Clean Connections
If corrosion was found during the diagnostic checks, use a high-quality electrical contact cleaner on the PL2 and PL4 module pins. Apply dielectric grease to the connector seals (not directly on the pins) to prevent future moisture intrusion.
Repair Wiring
If an open or short circuit was found in the CAN High or CAN Low wires, splice in a new section of wire using OEM-approved heat-shrink butt connectors, or replace the damaged section of the transmission wiring harness.
Replace Terminating Resistor
If the CAN bus resistance was out of spec (e.g., 120 ohms instead of 60 ohms) and wiring is intact, locate and replace the faulty CAN bus terminating resistor on that network segment.
Module Replacement
If the wiring, terminators, and software are all verified as good, the PL2 module is likely failing to broadcast its messages. Replace the PL2 module.
Reassembly and Calibration
Reconnect the battery. Connect the tractor to John Deere Service Advisor, clear the stored PL4 002167.09 fault code, and perform any required transmission calibrations for the DirectDrive system.
Test Drive
Operate the tractor, shifting through the DirectDrive ranges to ensure the park lock solenoids engage/disengage properly and the code does not return.
Parts you might need
(3)DirectDrive Control Module (PL2 / PL4)
Requires programming via Service Advisor upon installation.
CAN Bus Terminating Resistor
Generic John Deere CAN network (120-ohm)
Transmission Wiring Harness
John Deere 6R Series (DirectDrive specific)
Get help to fix this fault by requesting a quote