002354.06
John Deere 002354.06: High Amps Detected on Bonnet Corner Work Light Pin When Work Lights Are Turned On
Issue description
A high current is detected on the Bonnet Corner Work light pin of the Module when the Work lights are activated. This may be caused by a faulty bulb or a short to earth. The Main Control Module (BLC) is also identified as a potential source of the issue.
Check the cause
Bulb
Short to earth
Main Control Module (BLC)
Repair steps
Inspect the bulb
Check the Bonnet Corner Work light bulb for damage or failure.
Test for short to earth
Use a multimeter to test the circuit for a short to earth.
Check the Main Control Module (BLC)
Verify the functionality of the Main Control Module (BLC) and ensure it is properly connected.
Parts you might need
(0)Get help to fix this fault by requesting a quote