002358.06

John Deere 002358.06 – BLC / RLC: High Amps at Grab Rail Headlight/Work Light

Issue description

The Basic Light Control (BLC) or Roof Lighting Control (RLC) module has detected excessive electrical current draw on the circuit for the grab rail-mounted headlight high beam or an associated work light. This high-amperage condition is typically caused by a failing bulb drawing too much power or a short circuit to ground. The control module flags this error to prevent damage to the wiring harness and the module itself.

Applies to these machines

  • 6110M
  • 6120M
  • 6130M
  • 6145M
  • 6155M
  • 6175M
  • 6195M
  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 6090MC
  • 6090RC
  • 6100MC
  • 6100RC
  • 6110MC
  • 6110RC

Check the cause

  1. Park the machine on a level surface, stop the engine, remove the key, and disconnect the battery ground strap to prevent accidental shorts

  2. Visually inspect the grab rail headlight and associated work lights for cracked housings or water ingress

  3. Examine the wiring harness leading to the light assembly for chafing, pinched wires, or damaged insulation that could cause a short to the frame

  4. Check all accessible connectors for corrosion, bent pins, or loose connections

  5. Isolate the faulty component by disconnecting lights on the circuit one at a time and cycling the lights to see if the fault clears

  6. Test for a short circuit to ground in the wiring harness using a multimeter (check continuity between the power wire pin and a clean chassis ground)

  7. Test the light assembly itself for an internal short by checking for continuity between its power and ground pins

Repair steps

  1. Replace faulty bulb

    If a failing bulb is identified as the cause of the high current draw, replace it with a new one of the correct type. Do not touch the glass of a new halogen bulb with bare hands, as oils can cause premature failure.

  2. Repair wiring harness

    If a short to ground is found in the harness, repair the damaged section of wire. Solder the connection and seal it with heat-shrink tubing to protect it from moisture and vibration.

  3. Replace light assembly

    If the light assembly has an internal short circuit (very low resistance across power and ground pins), replace the entire assembly.

  4. Reassemble and clear codes

    Reconnect all components and the battery ground strap. Turn on the lights to verify proper operation, then use a diagnostic tool to clear the fault code from the BLC or RLC module.

Parts you might need

(8)

Get help to fix this fault by requesting a quote

Browse other John Deere codes