John Deere 002368.06 – CLC or FCC: High Amp Draw On Left Turn Signal
Issue description
The control module has detected an abnormally high amperage in the electrical circuit for the left-hand turn signal. This condition typically indicates a short circuit to ground or the use of an incorrect, high-wattage bulb. Excessive current flow can lead to blown fuses, damaged wiring, or failure of the control module's output driver.
Applies to these machines
25 machines- 7J Series
- 7210J
- 6090MC
- 6090RC
- 6100MC
- 6100RC
- 6110MC
- 6110RC
- 8030
- 8130
- 8230
- 8330
- 8430
- 8530
- 9030
- 9230
- 9330
- 9430
- 9530
- 9630
- 7020 Series
- 7220
- 7320
- 7420
- 7520
Check the cause
Restart the tractor and cycle the left turn signal to see if the code is intermittent and clears on its own
Inspect all left turn signal bulbs (front, rear, and implements) for shorted filaments, internal damage, or incorrect wattage
Inspect the wiring harness and connectors (especially the 7-pin implement connector) for chafed, pinched, or melted insulation causing a short to ground
Check for incorrect controller configuration settings in the CLC
Inspect the flasher control switch or relay for signs of overheating or internal failure
Repair steps
Inspect and replace bulbs
Access and remove all bulbs associated with the left turn signal circuit. Inspect for signs of a shorted filament or internal damage. Replace any incorrect or damaged bulbs with a new 12-volt, 21-watt bulb (e.g., part 57M7014).
Test wiring and implement connector
Disconnect the 7-pin implement connector to see if the fault code clears, which isolates the fault to the implement. If the fault persists, visually inspect the tractor's wiring harness and use a multimeter to check for continuity to ground on the power wire of the turn signal circuit.
Verify controller configuration
If the circuit and bulbs are in good condition, use a John Deere service tool to access CLC addresses 053 (Lighting Configuration 1) and 054 (Lighting Configuration 2). Ensure they match the tractor's actual lighting hardware. Check with a dealer for any available CLC software updates.
Test flasher control switch
If a separate flasher control switch is used, inspect it for signs of overheating or damage. Test the component by swapping it with an identical one from a different circuit to see if the fault follows the switch.
Parts you might need
(4)- Bulb, 12 Volts, 21 Watts57M7014
Common bulb for turn signal and brake light applications; 21 watts, 1.75 amps rating.
Left Side Turn Signal Lamp
TA14476Complete lamp assembly for various compact utility tractors.
Left Side Turn Signal Lamp
RE215149Complete lamp assembly for many 5-series tractors.
Rotary-style switch used on a wide variety of older tractors, combines, and sprayers.
Get help to fix this fault by requesting a quote