2370.06

John Deere 2370.06 – ICC or CLC: Right Turn Signal Lights Circuit Current High

Issue description

The controller has detected that the electrical current flowing to the right turn signal circuit is higher than the expected normal range, which typically points to a short circuit to ground (earth). This can be caused by a shorted wiring harness, a faulty bulb socket, or an internal failure within the control module.

Applies to these machines

  • 5085E
  • 5090E
  • 5090EL
  • 5100E
  • 5090M
  • 5100M
  • 5100MH
  • 5100ML
  • 5115M
  • 6110M
  • 6120M
  • 6130M
  • 6145M
  • 6155M
  • 6175M
  • 6195M
  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 5085M
  • 5115ML
  • 7630
  • 7730
  • 7830
  • 7930
  • 8430
  • 9230
  • 9330
  • 9430
  • 9530
  • 9630
  • 8310RT
  • 8335RT
  • 8360RT
  • 250D
  • 300D
  • 260E
  • 310E
  • 770G
  • 770GP
  • 772G
  • 772GP

Check the cause

  1. Inspect the right turn signal bulbs for melted or shorted internal filaments

  2. Examine the wiring harness and connectors leading to the right front and right rear turn signals, and cab roof module, for chafing, melted insulation, corrosion, or loose connections

  3. Use a digital multimeter to check for continuity to ground in the right turn signal circuit to locate potential ground faults

  4. Test the functionality of the ICC or CLC control module responsible for outputting the turn signal voltage

Repair steps

  1. Power Cycle

    Turn off the machine and restart the engine. If the code clears and does not return, it may have been a transient voltage spike.

  2. Bulb Replacement

    If the right turn signal bulb is burnt out or visibly damaged, replace it with the correct OEM wattage bulb.

  3. Harness Repair

    If a short to ground is found in the wiring harness (often where wires route through the cab roof or fenders), repair the damaged wire and secure it away from pinch points.

  4. Socket Replacement

    If the bulb socket is corroded or melted, replace the turn signal assembly.

  5. Module Replacement

    If the wiring and bulbs test perfectly but the circuit still reads high current directly out of the module pins, the ICC or CLC module has an internal short and must be replaced by a dealer.

  6. Clear Codes

    After repairs, clear the diagnostic trouble codes via the CommandCenter or diagnostic tool and test the right turn signal to ensure the code does not return.

Parts you might need

(5)
  • Right Hand Turn Signal Light Assembly

    RE215148

    5000 Series

  • Turn Signal Bulb (12V, 21/5W)

    M136357
  • Turn Signal Bulb (12V, 21W)

    57M7014
  • Turn Signal Bulb

    RE321841

    8000 Series

  • Amber Warning Light Assembly

    RE217551

Get help to fix this fault by requesting a quote