John Deere 2392.03 – CLC / VCU: Back Up Alarm Circuit Voltage High
Issue description
The controller has detected a short to power in the backup alarm or backup light circuit.
Applies to these machines
22 machines- 6110R
- 6120R
- 6130R
- 6145R
- 6155R
- 6175R
- 6195R
- 6215R
- 8245R
- 8270R
- 8295R
- 8320R
- 8335R
- 8345R
- 8370R
- 8400R
- 250D Series II
- 300D Series II
- 310SK
- 315SK
- 325SK
- 710K
Check the cause
Visually inspect the wiring harness and connectors running from the CLC (or VCU) to the backup alarm and backup lights for chafing, melting, or exposed wires that could cause a short to power.
Use a multimeter to test the backup alarm circuit for a short to a power source by checking the voltage at the backup alarm connector while the machine is in reverse.
Disconnect the backup alarm and backup lights to see if the short to power clears. If the code changes to an open circuit or clears, the component itself is internally shorted.
Test the pressure backup alarm switch or mechanical reverse switch for internal shorts or sticking.
Repair steps
Disconnect Power
Always disconnect the battery or turn off the battery isolator switch before performing electrical repairs to prevent further damage to the CLC/VCU.
Isolate the Short
Based on the multimeter readings, trace the wiring harness back from the alarm to the controller to locate the exact point of the short to power.
Repair Wiring
If a damaged wire is found, repair the section using OEM-approved waterproof splices and heat shrink, or replace the affected harness section.
Replace Components
If the wiring is intact but the backup alarm or switch is internally shorted, remove the faulty component and install a new OEM replacement.
Reassemble and Test
Reconnect the battery, clear the stored fault codes from the CLC/VCU, and shift the machine into reverse to verify the backup alarm sounds and the code does not return.
Parts you might need
(12)Backup Alarm
AT373664Various Models
Backup Alarm
KV18230Various Models
Backup Alarm
LVA11758Various Models
Backup Alarm
AZ101663Various Models
Backup Alarm
AT78534Various Models
Backup Alarm
SJ21985Various Models
Backup Alarm Kit
BTC10673Backup Alarm Kit
BM26351Pressure Backup Alarm Switch
AL176308Tractors
Pressure Backup Alarm Switch
AT159811Backhoes
Pressure Backup Alarm Switch
AT159811ABackhoes
Bracket, Backup Alarm
R5495938R Series
Get help to fix this fault by requesting a quote