2629.04

John Deere 2629.04 – Engine Control Unit (ECU): Fixed Turbocharger Compressor Outlet Temperature Signal Out of Range Low

Issue description

The Engine Control Unit (ECU) has detected that the voltage from the fixed turbo outlet temperature sensor is below the expected level (typically below 0.1V). This low voltage condition prevents the ECU from accurately monitoring the temperature of the air exiting the fixed-geometry turbocharger, which can affect engine management and monitoring in twin-turbo systems.

Applies to these machines

  • 6110M
  • 6120M
  • 6130M
  • 6145M
  • 6155M
  • 6175M
  • 6195M
  • 6110R
  • 6120R
  • 6130R
  • 6145R
  • 6155R
  • 6175R
  • 6195R
  • 6215R
  • 8R Series
  • 8RT Series
  • 8RX Series
  • 8245R
  • 8400R
  • 8310RT
  • 8335RT
  • 8360RT
  • 9R Series
  • 9RT Series
  • 9RX Series
  • 9410R
  • 9460R
  • 9510R
  • 9560R
  • S-Series Combines
  • S680
  • S685
  • S690
  • 7000 Series Forage Harvesters
  • 7180
  • 7280
  • 7380
  • 7480
  • 7580
  • 7780
  • 7980
  • 744K
  • 824K
  • 844K

Check the cause

  1. Examine the compressor outlet temperature sensor and its wiring harness for signs of chafing, melting, or physical damage.

  2. Use a multimeter to check the voltage at the sensor connector (a reading below 0.5V triggers this code).

  3. Test the circuit for continuity to ensure there are no unwanted paths to ground (short to ground).

  4. Remove the sensor and check if it is heavily plugged up with soot or carbon.

  5. Note: If a new sensor does not resolve the code, the issue is highly likely a broken wire or short in the engine wiring harness rather than the sensor itself.

Repair steps

  1. Power Down

    Turn off the engine, remove the key, and disconnect the battery to ensure safety and prevent electrical spikes.

  2. Locate the Sensor

    On twin-turbo engines, the sensor is located on the interstage compressor air duct (the tube between the two turbos). For example, on a 9460R, it is found on the 4-inch U-shaped intake tube.

  3. Disconnect

    Unplug the electrical connector from the temperature sensor.

  4. Remove

    Use a wrench to carefully unscrew the faulty sensor from the air duct.

  5. Install

    Thread the new OEM temperature sensor into the air duct and tighten it to the manufacturer's torque specifications.

  6. Reconnect

    Plug the electrical harness back into the sensor, ensuring the locking tab clicks into place.

  7. Clear Codes

    Reconnect the battery, turn the ignition on, and use a diagnostic scan tool to clear the ECU 002629.04 fault code.

  8. Test

    Start the engine and run it under operational conditions to verify the code does not return.

Parts you might need

(3)
  • Fits John Deere 9.0L and 13.5L engines. Replaces older casting numbers such as RE537636.

  • Required if the mounting threads on the tube are stripped or damaged.

  • General John Deere temperature sensor; compatibility with this specific twin-turbo application is not confirmed.

Get help to fix this fault by requesting a quote

Browse other John Deere codes