John Deere 3361.31 – ECU: DEF Dosing Injector Active Without Injection
Issue description
The Engine Control Unit (ECU) commanded the Diesel Exhaust Fluid (DEF) dosing injector to open, but it did not detect the expected corresponding drop in DEF pressure. This indicates that the injector is mechanically stuck closed, clogged, or failing to actuate, meaning no DEF is actually being injected into the exhaust stream.
Applies to these machines
53 machines- 5085E
- 5090E
- 5090EL
- 5100E
- 5090M
- 5100M
- 5100MH
- 5100ML
- 5115M
- 6110M
- 6120M
- 6130M
- 6145M
- 6155M
- 6175M
- 6195M
- 6110R
- 6120R
- 6130R
- 6145R
- 6155R
- 6175R
- 6195R
- 6215R
- 250GLC
- 300GLC
- 350GLC
- 380GLC
- 624K
- 644K
- 724K
- 744K
- 824K
- 844K
- 750K
- 850K
- 1050K
- 670G
- 672G
- 5M Series
- 5085M
- 5095M
- 6105M
- 8R Series
- 8RW Series
- 9R
- 9RT
- 9470RT
- 9520RT
- 9570RT
- 9RX Series
- S7 Series
- X9 Series
Check the cause
Examine the DEF dosing injector and surrounding lines for physical obstructions, severe mechanical wear, or external leaks.
Use a diagnostic tool (like John Deere Service ADVISOR) to manually command the injector to open and verify if the actuator responds to control signals.
Remove the injector from the exhaust pipe (leaving the fluid and electrical lines connected) and perform a pressure test to check the spray pattern. If the injector does not fire properly or the spray pattern is distorted/absent, the injector has failed.
Repair steps
Remove the Dosing Injector
Disconnect the electrical harness and DEF supply line from the DEF dosing injector. Unbolt and remove the injector from the exhaust aftertreatment assembly.
Bench/Spray Test
Perform the spray pattern test mentioned in the diagnostics phase to definitively condemn the part.
Install New Injector
If the injector is not firing properly, install a new DEF dosing injector. Torque mounting bolts to OEM specifications and reconnect the DEF fluid line and electrical connector.
Force a Regeneration
Put the machine into a forced stationary regeneration (regen) cycle using your diagnostic tool.
Monitor the Regen
Allow the unit to run through the complete regen cycle (this can take up to 3 hours depending on soot/DEF load) to ensure the SCR system is dosing correctly and temperatures are nominal.
Clear Codes and Test
Once the regen is complete, clear the 003361.31 fault code from the ECU. Run and test the machine under load to verify the code does not return.
Parts you might need
(5)DEF Dosing Injection Nozzle
RE560468Fits most mid-size construction equipment (250GLC-380GLC excavators, 624K-724K loaders, 670G/672G graders). (Bosch cross-reference: 0444043045, 0444043041)
DEF Dosing Injector
RE555626Fits larger construction equipment (744K, 824K, 844K loaders; 750K, 850K, 1050K dozers). (Bosch cross-reference: 0444043046)
DEF Dosing Injector
DZ113622Fits heavy ag equipment including 9R/9RT/9RX tractors and S7/X9 combines.
DEF Dosing Injector
MIA884456Alternative DEF Dosing Injector part numbers depending on specific engine/chassis configurations.
DEF Dosing Injector
REC437671600Alternative DEF Dosing Injector part numbers depending on specific engine/chassis configurations.
Get help to fix this fault by requesting a quote