John Deere 003509.03: Issue With 5v Supply Over 5v Detected in PTD Range Control Module Direct Drive

Issue description

The system has detected an overvoltage condition in the 5v supply for the PTD Range Control Module Direct Drive. This may indicate a fault in the power regulation or a malfunction in the component identified by this code.

Check the cause

  1. The 5v supply voltage

  2. The PTD Range Control Module Direct Drive

  3. The Range Module Direct Drive

Repair steps

  1. Verify the 5v supply voltage

    Use a multimeter to measure the voltage at the 5v supply point. Ensure it is within the specified range.

  2. Inspect the PTD Range Control Module Direct Drive

    Check for visible damage, loose connections, or signs of overheating on the PTD Range Control Module Direct Drive.

  3. Inspect the Range Module Direct Drive

    Check for visible damage, loose connections, or signs of overheating on the Range Module Direct Drive.