003599.03
John Deere 003599.03: High 12 Volt Supply Voltage Detected
Issue description
The system has detected that the 12 Volt Supply Voltage is higher than expected. This condition is reported by the Cab Control Module (DOI).
Check the cause
The 12 Volt Supply Voltage using a multimeter
The Cab Control Module (DOI) for proper operation
Repair steps
Measure the 12 Volt Supply Voltage
Use a multimeter to verify the voltage level at the 12 Volt supply circuit.
Inspect the Cab Control Module (DOI)
Check the Cab Control Module (DOI) for signs of damage or improper installation.
Parts you might need
(0)Get help to fix this fault by requesting a quote